IoT Smart Water Meters with the Option of LoRaWAN or NB-IoT
Are you in the business of supplying water to communities or managing real estate properties? We have a game-changing solution for you!
Introducing
our Wireless Remote Water Meter – a cutting-edge innovation built on the
foundation of traditional wired meters, but with a wireless twist. With added
routing capabilities, the installation and setup are a breeze, effortlessly
creating a seamless network. Say goodbye to complex wiring issues and hello to
simplicity!
But that's not all.
We're taking it a step further with our Wireless Valve Remote Control Water
Meter. Building upon the wireless remote meter, we've incorporated valve
control features. Now, you can say farewell to the woes of users maliciously
delaying payments and the challenges of fee collection. With this solution,
you'll gain real-time remote monitoring, remote valve control, and even prepaid
functionality.
It's time to
streamline your water management, save time, and enhance efficiency with our
wireless water meter solutions. Join us in the future of water management
today!
Pioneering Smart Water Solutions for a Brighter Tomorrow!
RF Parameters:
LoRaTM Modem:
Power Consumption:
Please let us know if you require any further technical details or have specific questions regarding this product.
Working conditions:
Parameter
Min.
Type
Max.
Units
Operating Voltage
2.3
3.6
3.7
V
Power on time
-
-
100
ms
Working temperature range
-20
25
75
℃
Operating humidity range
10
-
90
%rh
Voltage
-0.5
-
3.8
V
I/O Level
-0.3
-
VDD+0.3
V
storage temperature
-40
-
125
℃
The straight pipe length before the water meter should be 10 times the diameter (DN), and the straight pipe length after the water meter should be 5 times the diameter (DN). Ensure that the flow direction aligns with the arrow on the meter body.
Power Supply Requirements:
The acceptable voltage for both alternating current (AC) and direct current (DC) should fall within a range of -15% to +10% of the standard voltage. Additionally, the frequency of AC power should be within ±2% of the standard frequency.
Main technical parameters:
Model-DN
Flow range
Q3
Q4
Q2
Q1
Min. reading
Max.
reading
Q3/Q1
Q2/Q1
m3/h
m3
DN-15
80
1.6
2.5
3.125
0.05
0.03125
0.0001
999999
DN-20
80
1.6
4.0
5.0
0.08
0.05
0.0001
999999
DN-25
80
1.6
6.3
7.875
0.126
0.07875
0.0001
999999
Contact: Jeffrey Bao
Phone: +86 15058513203
Tel: +86 57981329300
Email: jeffrey_bao@outlook.com
Add: No.257 East Huifeng Road, Yinzhou District, Ningbo, Zhejiang, China